Professional Grade Electrical

Electrical Wires & Cables

Premium quality building wire, NM-B Romex, MC cable, underground feeder, and specialty wire for residential, commercial, and industrial applications. All products meet NEC requirements and carry UL listings.

Residential Wire

NM-B Romex, THHN, and MC cable for homes

Commercial Grade

MC, tray cable, and XHHW for commercial projects

Direct Burial

UF-B and USE-2 rated for underground installation

UL Listed Products
NEC Compliant
Fast Nationwide Shipping
Expert Technical Support
100% Copper Guaranteed
500+
Wire Products
14-4/0
AWG Range
100%
UL Listed
24/7
Expert Support

Shop by Wire Type

Select the wire type that matches your project requirements. All products meet NEC code requirements.

NM-B (Romex)
Standard residential wiring
THHN/THWN
Building wire for conduit
MC Cable
Metal clad for commercial
UF-B
Underground feeder cable
SER/SEU
Service entrance cable
SOOW
Portable power cord
XHHW
High-temp rated wire
Tray Cable
Industrial cable tray

Electrical Wire & Cable Products

Browse our complete selection of UL-listed electrical wire and cable. Cut-to-length and bulk spools available.

0 products

Wire Gauge Calculator

Determine the correct wire size for your electrical installation based on amperage, distance, and voltage.

Calculate Your Wire Size

Enter your circuit specifications to find the recommended AWG wire gauge.

Voltage Drop
2.8%
Min. Breaker Size
30A
For a 20A load at 100 feet on 120V, we recommend 10 AWG copper wire to keep voltage drop under 3%. Always verify with local codes and a licensed electrician.

Find the Right Cable Type

Answer a few questions and we will recommend the best wire type for your project.

Cable Type Finder

Tell us about your installation and we will match you with the right product.

1. Where will this wire be installed?

Interior Walls
In Conduit
Underground
Exposed/Surface

2. What type of building?

Residential
Commercial
Industrial
Outdoor/Landscape

3. Will it be exposed to moisture or wet conditions?

Dry Only
Damp Locations
Wet Locations
Direct Burial

Recommended Cable Type

NM-B (Romex)

NM-B cable is the standard choice for residential interior wiring in dry locations. It includes a bare ground wire and is easy to install in wood-framed construction.

UL Listed NEC Compliant With Ground

Wire Application Guide

Quick reference for selecting the right wire type based on your specific application.

Residential

Standard home wiring for outlets, switches, and lighting circuits in wood-frame construction.

NM-B (Romex) - Primary choice
THHN - In conduit runs
UF-B - Outdoor/underground

Commercial

Office buildings, retail spaces, and commercial structures requiring metal protection.

MC Cable - Most common
THHN in EMT conduit
AC (BX) - Flexible runs

Underground

Direct burial applications for outdoor lighting, detached buildings, and landscape power.

UF-B - Direct burial rated
USE-2 - Service entrance
THWN in PVC conduit

AWG Wire Size Reference Chart

Quick reference for wire ampacity ratings based on NEC Table 310.16 for copper conductors at 75°C.

AWG Size Diameter (inches) Max Amps (75°C) Typical Breaker Common Uses
14 AWG 0.0641 15A 15A Lighting circuits, general outlets
12 AWG 0.0808 20A 20A Kitchen, bathroom outlets, most circuits
10 AWG 0.1019 30A 30A Dryers, water heaters, A/C units
8 AWG 0.1285 40A 40A Ranges, large A/C, EV chargers
6 AWG 0.1620 55A 50A Subpanels, large appliances
4 AWG 0.2043 70A 60A Feeder circuits, service entrance
2 AWG 0.2576 95A 90A 100A subpanels, large feeders
1/0 AWG 0.3249 125A 100A Service entrance, main feeders
2/0 AWG 0.3648 145A 125A 150A services
4/0 AWG 0.4600 195A 200A 200A main service entrance

Important Note

Ampacity values are for copper conductors in raceway or cable with not more than 3 current-carrying conductors. Actual ampacity may be reduced based on ambient temperature, conduit fill, and other factors. Always consult NEC tables and local codes for your specific installation.

Complete Guide to Electrical Wires and Cables

Selecting the correct electrical wire is fundamental to any safe, code-compliant electrical installation. Whether you are wiring a new home, upgrading a commercial building, or running power to an outdoor structure, understanding wire types, sizes, and applications ensures your project meets both safety requirements and performance expectations.

Understanding Wire Types and Their Applications

Different installation environments demand specific wire types. NM-B cable, commonly known by the brand name Romex, serves as the backbone of residential electrical systems. This sheathed cable contains multiple insulated conductors plus a bare ground wire, all wrapped in a protective plastic jacket. NM-B is approved for dry, indoor locations in residential construction where the cable can be protected within walls, floors, and ceilings.

Commercial and industrial installations typically require metal-clad (MC) cable or individual conductors in metal conduit. MC cable provides the mechanical protection and grounding required by commercial building codes while offering easier installation than traditional conduit systems. For conduit installations, THHN/THWN wire provides the heat resistance and moisture protection needed for these demanding environments.

Choosing the Correct Wire Size

Wire gauge selection depends on three primary factors: the circuit's amperage requirement, the distance from the panel to the load, and the acceptable voltage drop. The National Electrical Code establishes minimum wire sizes based on ampacity, the amount of current a conductor can safely carry without overheating. However, long wire runs may require upsizing to compensate for voltage drop.

For most residential circuits, 14 AWG wire supports 15-amp circuits while 12 AWG handles 20-amp loads. Kitchen and bathroom outlets typically require 20-amp circuits with 12 AWG wire. Larger appliances like dryers, ranges, and HVAC equipment need 10 AWG or larger conductors depending on their amperage requirements.

Underground and Direct Burial Wiring

Running power underground to detached garages, workshops, or outdoor lighting requires wire specifically rated for burial. UF-B (Underground Feeder) cable can be directly buried without conduit at code-specified depths. Its solid, moisture-resistant jacket protects against groundwater and soil chemicals. For higher amperage runs like service feeders, USE-2 wire provides the necessary ratings for underground service entrance applications.

Always check local codes for burial depth requirements, which typically range from 12 to 24 inches depending on the wire type, voltage, and whether conduit is used. Installing underground wire in conduit provides additional mechanical protection and makes future wire replacement possible without excavation.

Specialty Wire Applications

Beyond standard building wire, specialty applications demand purpose-built products. SOOW cord provides portable power for temporary installations, equipment connections, and industrial applications requiring flexibility and durability. Welding cable handles the extreme amperages of welding equipment with highly flexible stranded conductors.

Low voltage wiring for doorbells, thermostats, and landscape lighting uses smaller gauge wire with different insulation requirements than line voltage circuits. Speaker wire, network cable, and coaxial cable serve communication and entertainment systems with their own selection criteria and installation requirements.

Frequently Asked Questions

Common questions about electrical wire and cable selection answered by our experts.

What size wire do I need for a 20 amp circuit?
A 20 amp circuit requires 12 AWG copper wire minimum per NEC code. For runs over 100 feet, consider upsizing to 10 AWG to minimize voltage drop. Always use wire rated for your specific application, such as NM-B for residential interior or THHN for conduit installations.
What is the difference between THHN and THWN wire?
THHN is rated for dry and damp locations with a maximum temperature of 90°C. THWN adds wet location rating with a 75°C maximum in wet conditions. Most modern wire is dual-rated THHN/THWN, suitable for both dry and wet locations, making it versatile for various installations.
Can I use NM-B (Romex) in a garage?
NM-B cable can be used in attached garages where it is protected within finished walls or ceilings. In unfinished garages with exposed framing, NM-B may be acceptable if protected from physical damage. Some jurisdictions require conduit or MC cable in garages. Check your local codes and inspection requirements.
How deep do I need to bury UF-B cable?
UF-B cable burial depth depends on the circuit voltage and protective measures. For 120V circuits, UF-B requires 24 inches of cover when directly buried, 18 inches under a 2-inch concrete pad, or 12 inches under a concrete sidewalk. Installing in PVC conduit allows shallower burial depths. Always verify with local codes.
What wire do I need for an electric car charger?
Most Level 2 EV chargers require a 240V, 40-50 amp circuit. This typically requires 6 AWG copper wire for up to 55 amps, though you should size based on the charger's specific amperage and the wire run length. Use wire appropriate for your installation type, such as NM-B for interior runs or THWN in conduit for garage installations.
Is solid or stranded wire better?
Solid wire is preferred for permanent installations in smaller gauges (14-10 AWG) because it holds its shape when terminated and pushes easily through conduit. Stranded wire is more flexible and preferred for larger gauges and applications requiring flexibility. Both are acceptable for most residential and commercial applications when properly terminated.
Do you sell wire by the foot?
Yes, we offer cut-to-length wire on many products, allowing you to purchase exactly what you need. We also stock standard spool sizes including 25, 50, 100, 250, 500, and 1000 foot rolls. Contact us for bulk pricing on large orders or custom cut lengths.
What is the difference between copper and aluminum wire?
Copper wire has better conductivity and requires smaller gauge for the same ampacity. Aluminum costs less but requires larger wire sizes and special terminations rated for aluminum. Aluminum is commonly used for service entrance cable and large feeder runs where the cost savings outweigh the size increase. Most branch circuits use copper.

Ready to Wire Your Project?

Get the right wire for the job with expert guidance and fast shipping. Bulk pricing available for contractors and large projects.